Product categories
News center
- Our UDI Medical Device Unique Id
- Our independently developed envi
- The environmental monitoring sys
- The first glacier real-time moni
- 4G real-time "watching" Yulong S
- HENGCHUANG IOT RFID Management c
- Our RFID electric vehicle manage
- Our intelligent warehouse manage
- Warmly celebrate the launch of H
- Our long-distance RFID identific
- Our company undertook the constr
- The pollutant Internet of things
- Our customized Internet of thing
Contact us
- Add: HeFei AnHui China
- Tel: 13635606601
- Fax: 0
- Email: 276786103@qq.com
Product show
Ox horn five parameter sensor (wind speed, wind direction, PM2.5, PM10, noise)
Product Numbers:202252495733
Price:-
Product introduction:At the same time, monitor the wind speed, wind direction and PM2 5. PM10, noise, many measurement elements, novel style, high integration, light and compact, convenient installation; Wind speed measurement range: 0 ~ 45m / s, 0 ~
At the same time, monitor the wind speed, wind direction and PM2 5. PM10, noise, many measurement elements, novel style, high integration, light and compact, convenient installation; Wind speed measurement range: 0 ~ 45m / s, 0 ~ 70m / s optional
Accuracy: ± (0.3 + 0.03V) m / S (V: wind speed) resolution: 0.1m/s wind direction measurement range: 0 ~ 360 °, accuracy: ± 3 °, resolution: 1 °, temperature measurement range: - 50 ~ 100 ° C, accuracy: ± 0.5 ° C, resolution:
Rate: 0.1 ° C; PM2. 5. Measuring range: 0 ~ 1000ug / m3, accuracy: ± 10%, resolution
Rate: 1 ug / m3 PM2 5. Measuring range: 0 ~ 2000ug / m3, accuracy: ± 10%, resolution
Rate: 1 ug / m3
Noise measurement range: measuring range: 30 ~ 130dB, accuracy: ± 7dB, resolution
Rate: 0.1dB
Power supply mode: DC12 ~ 24V output mode: RS485, four wire signal output: RS-485 signal: support Modbus Protocol (baud rate 9600 can be set,
Address (0-255 can be set) storage temperature: - 50 ° C ~ 80 ° c operating environment: temperature - 40 ° C ~ 60 ° C humidity 0 ~ 85%
Protection grade: IP66
Accuracy: ± (0.3 + 0.03V) m / S (V: wind speed) resolution: 0.1m/s wind direction measurement range: 0 ~ 360 °, accuracy: ± 3 °, resolution: 1 °, temperature measurement range: - 50 ~ 100 ° C, accuracy: ± 0.5 ° C, resolution:
Rate: 0.1 ° C; PM2. 5. Measuring range: 0 ~ 1000ug / m3, accuracy: ± 10%, resolution
Rate: 1 ug / m3 PM2 5. Measuring range: 0 ~ 2000ug / m3, accuracy: ± 10%, resolution
Rate: 1 ug / m3
Noise measurement range: measuring range: 30 ~ 130dB, accuracy: ± 7dB, resolution
Rate: 0.1dB
Power supply mode: DC12 ~ 24V output mode: RS485, four wire signal output: RS-485 signal: support Modbus Protocol (baud rate 9600 can be set,
Address (0-255 can be set) storage temperature: - 50 ° C ~ 80 ° c operating environment: temperature - 40 ° C ~ 60 ° C humidity 0 ~ 85%
Protection grade: IP66